Prowirl D 200 dual-sensor vortex flowmeter for steam, gas, and liquid measurement. DN15–DN300, integrated P&T compensation, measures volume flow, mass flow, and energy.

Prowirl D 200 – Dual-Sensor Vortex Flowmeter

The Endress+Hauser Prowirl D 200 features dual piezoelectric sensors for enhanced reliability. It is ideal for steam, gas, and liquid flow measurement with integrated pressure and temperature compensation for accurate volumetric and mass flow calculation.

Key Features

  • Nominal diameter: DN15 to DN300
  • Dual piezoelectric sensor design for redundancy
  • Integrated pressure and temperature compensation
  • Measures: Volume flow, mass flow, energy flow
  • Process temperature: –200 to +400°C
  • Process pressure: Up to 100 bar
  • Accuracy: ±0.75% (liquids), ±1.0% (gas/steam)
  • Communication: HART, PROFIBUS DP/PA, Foundation Fieldbus, EtherNet/IP

Applications

  • Steam distribution and energy metering
  • Compressed air and gas metering
  • Chemical and petrochemical processes
  • Power plant steam measurement
  • HVAC and building energy management

Technical Specifications

Parameter Specification
Measuring principle Vortex shedding
Nominal diameter DN15–DN300
Accuracy (liquid) ±0.75% of reading
Accuracy (gas/steam) ±1.0% of reading
Process temperature –200 to +400°C
Process pressure Up to 100 bar
Protection class IP67/IP68
Communication HART, PROFIBUS DP/PA, Foundation Fieldbus, EtherNet/IP
Approvals ATEX, IECEx, cCSAus, MID