Indumax CLS50D – Inductive Conductivity Sensor with Memosens
The Endress+Hauser Indumax CLS50D uses the inductive (toroidal) measurement principle, making it completely electrode-free and resistant to fouling, coating, and chemical attack. Ideal for measuring conductivity in aggressive, concentrated, or contaminated liquids.
Key Features
- Inductive (toroidal) measurement – no electrodes
- Conductivity range: 10 μS/cm to 2000 mS/cm
- Memosens digital technology
- Temperature range: –20 to +130°C
- Pressure range: 0 to 16 bar
- Materials: PEEK, PVDF, PFA
Applications
- Concentrated acid and base measurement
- Chemical process conductivity monitoring
- Electroplating bath control
- Pulp and paper process monitoring
- Food and beverage CIP monitoring
Technical Specifications
| Parameter | Specification |
|---|---|
| Measuring principle | Inductive (toroidal) |
| Conductivity range | 10 μS/cm–2000 mS/cm |
| Temperature range | –20 to +130°C |
| Pressure range | 0–16 bar |
| Sensor material | PEEK, PVDF, PFA |
| Signal type | Memosens digital |