t-mass F 500 | Thermal Mass Flowmeter for Gases

The t-mass F 500 is a thermal mass flowmeter for direct mass flow measurement of gases, featuring a flanged design for permanent installation in industrial gas applications.

t-mass F 500 – Thermal Mass Flowmeter for Gases

The Endress+Hauser t-mass F 500 measures gas mass flow directly using the thermal dispersion principle, without the need for pressure and temperature compensation. Its flanged design ensures a secure, leak-free installation.

Key Features

  • Measuring principle: Thermal dispersion (constant temperature difference)
  • Nominal diameter: DN25 to DN300
  • Accuracy: ±1.5% of reading + ±0.5% of full scale
  • Direct mass flow measurement (no P/T compensation needed)
  • Process temperature: −40 to +100 °C
  • Process pressure: up to 40 bar
  • Communication: HART 7, PROFIBUS PA, Modbus
  • Heartbeat Technology
  • Protection: IP66/IP67

Applications

Compressed air, nitrogen, natural gas, biogas, flare gas, industrial gases, energy management.

Technical Specifications

Parameter Value
Nominal diameter DN25–DN300
Accuracy ±1.5% of reading + ±0.5% of FS
Process temperature −40 to +100 °C
Process pressure Up to 40 bar
Communication HART 7, PROFIBUS PA, Modbus