Liquicap M FMI51 | Capacitance Level Transmitter for Liquids

The Liquicap M FMI51 is a capacitance level transmitter for continuous level measurement of conductive and non-conductive liquids in process tanks and vessels.

Liquicap M FMI51 – Capacitance Level Transmitter

The Endress+Hauser Liquicap M FMI51 uses the capacitance measuring principle for continuous level measurement in liquids. Its fully insulated probe is suitable for both conductive and non-conductive media.

Key Features

  • Measuring principle: Capacitance
  • Measuring range: up to 4 m (rod probe), up to 32 m (rope probe)
  • Accuracy: ±2 mm
  • Suitable for conductive and non-conductive liquids
  • Process temperature: −50 to +150 °C
  • Process pressure: −1 to +40 bar
  • Probe materials: PTFE-insulated, 316L
  • Output: 4–20 mA HART, PROFIBUS PA
  • Explosion protection: ATEX, IECEx

Applications

Chemical tanks, water tanks, oil storage, food and beverage vessels, pharmaceutical tanks. Suitable for conductive and non-conductive liquids.

Technical Specifications

Parameter Value
Measuring principle Capacitance
Measuring range Up to 4 m (rod) / 32 m (rope)
Accuracy ±2 mm
Process temperature −50 to +150 °C
Process pressure −1 to +40 bar
Communication HART, PROFIBUS PA